Track the runtime (ON time) of your machines along with two additional inputs and location.
RED ---> BATTERY+ (constant 10-30V)
BLACK ---> BATTERY-
YELLOW/DIN1 ---> IGNITION
GREEN-WHITE/DIN2 ---> OPTIONAL
WHITE/DIN3 ---> OPTIONAL
IGNITION: This will indicate the ON time of your machine, showing up as green bars on the platform under the Runtime pane in the Statistics tab.

This input detects positive voltages ranging from 7-30V. Make sure to wire it to a spot in the machine where voltage is present when the machine is turned ON and voltage is absent when the machine is turned OFF, otherwise the installation will not work properly.
GREEN-WHITE/WHITE: It is possible to get green bars for two additional inputs, similarly to the picture above. You can wire those inputs to anything you would like to track as long as the voltage ranges from 2.5V-30V representing ON state/activity. The same logic applies in terms of voltage being present and absent.
With cleaning machines, the inputs usually track brush motors and vacuum motors.
You can track the green bars under the corresponding menu item under the Statistics pane.

To put down an order for this item, please write an email to orders@toolsense.io noting the item code and quantity of the required item(s).
Order Codes:
TSIOT-FMC130-STD for Europe
TSIOT-FMC130-APAC-STD for Asia Pacific
TSIOT-FMC13A-STD for North America
Some machines might switch ground to activate a motor. In such a case we can invert the logic on the software side only on the additional inputs DIN2 (green-white) and DIN3 (WHITE).

This type of configuration has a separate order code.
Order Codes:
TSIOT-FMC130-GND for Europe
TSIOT-FMC130-APAC-GND for Asia Pacific
TSIOT-FMC13A-GND for North America